Installation Temperature: The installation temperature should be over 0℃. If the ambient temperature is lower than 0℃, the cable should be preheated.
Joto la Uendeshaji: Max permissible continuous operating temperature of the conductor shall not exceed 90℃.
Conductor Short-circuit Temperature: Max temperature at short-circuit shall not exceed 250℃ . The short-circuit duration shall not exceed 5 seconds.
Kipenyo cha Kukunja: 20( d+D) +/-5% for single core cable,15( d+D )+/-5% for multi-core cable.
D=Actual outer diameter of cable (mm),d=Actual diameter of the conductor (mm)
Kawaida: IEC60502, GB/T12706, or other standard required by the customer. The requirements for flame retardant property are according to IEC60332-3 and GB18380.
Ufungashaji: Reel ya chuma/mbao, reel ya mbao, au reel ya chuma.

Maelezo |
Application |
Cu or Al conductor/ XLPE insulated/ PVC sheathed power cable |
It is installed in indoor or outdoor,and can be pulled with a proper force during installation ,but unable to bear external mechanical force.Single core cable is not permitted to install in magnetic duct. |
Cu or Al conductor/ XLPE insulated/ PVC sheathed flame retardant power cable |
|
Cu or Al conductor/ XLPE insulated/ steel tape armored/ PVC sheathed power cable |
It is installed under ground and able to bear external mechanical force,but unable to bear large pulling force. |
Cu or Al conductor/ XLPE insulated steel tape armored/ PVC sheathed flame retardant power cable |
|
Cu or Al conductor/ XLPE insulated/ steel wire armored/ PVC sheathed power cable |
It is installed under water or where the cable route is with large difference of level.It is able to bear external mechanical force and proper pulling force. |
Cu or Al conductor/ XLPE insulated/ steel wire armored/ PVC sheathed flame retardant power cable |

Type |
No of Cores |
Rated Voltage (kV) |
||||||
0.6/1 |
3.6/6 |
6/6 6/10 |
8.7/10 8.7/15 |
12/20 |
21/35 |
26/35 26/45 |
||
Nominal Area of Conductor (sq.mm) |
||||||||
CU or AL/XLPE/PVC |
1 |
1.5 to 240 |
25 to 500 |
25 to 500 |
25 to 500 |
35 to 500 |
50 to 500 |
50 to 500 |
3 |
1.5 to 240 |
25 to 300 |
25 to 300 |
25 to 300 |
35 to 300 |
--- |
--- |
|
CU or AL/XLPE/STA/PVC |
3 |
10 to 240 |
25 to 300 |
25 to 300 |
25 to 300 |
35 to 300 |
--- |
--- |
CU or AL/XLPE/SWA/PVC |
3 |
10 to 240 |
25 to 300 |
25 to 300 |
25 to 300 |
35 to 300 |
--- |
--- |
*1kV 4-core XLPE cable is also in our supply range.

Construction of 0.6/1 kV 1-core
CU or AL/XLPE Insulated/ PVC Sheathed Power Cable

No |
Construction and materials |
1 |
Copper or aluminum conductor |
2 |
XLPE insulation |
3 |
Non-flame retardant or flame retardant PVC sheath |
Technical Characteristics of 0.6/1kV for CU or AL conductor/XLPE Insulated/PVC Sheathed Power Cable, 1-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
1x 1.5 |
0.7 |
1.5 |
6 |
12.1 |
--- |
53 |
--- |
1x2.5 |
0.7 |
1.5 |
6 |
7.41 |
12.1 |
68 |
53 |
1x4 |
0.7 |
1.5 |
7 |
4.61 |
7.41 |
87 |
64 |
1x6 |
0.7 |
1.5 |
7 |
3.08 |
4.61 |
110 |
73 |
1x10 |
0.7 |
1.5 |
8 |
1.83 |
3.08 |
155 |
95 |
1x16 |
0.7 |
1.5 |
9 |
1.15 |
1.91 |
220 |
120 |
1x25 |
0.9 |
1.5 |
10 |
0.727 |
1.20 |
345 |
190 |
1x35 |
0.9 |
1.5 |
12 |
0.524 |
0.868 |
424 |
207 |
1x50 |
1.0 |
1.5 |
13 |
0.387 |
0.641 |
555 |
245 |
1x70 |
1.1 |
1.5 |
14 |
0.268 |
0.443 |
770 |
336 |
1x95 |
1.1 |
1.5 |
16 |
0.193 |
0.320 |
1040 |
455 |
1x 120 |
1.2 |
1.5 |
18 |
0.153 |
0.253 |
1290 |
550 |
1x 150 |
1.4 |
2.0 |
21 |
0.124 |
0.206 |
1590 |
650 |
1x 185 |
1.6 |
2.0 |
23 |
0.0991 |
0.164 |
1944 |
804 |
1x240 |
1.7 |
2.0 |
25 |
0.0754 |
0.125 |
2510 |
1021 |
Construction of 3.6/6kV to 26/35kV, 1- core, CU or AL conductor/XLPE Insulated/ PVC Sheathed Power Cable

No |
Construction and materials |
1 |
Copper or aluminum conductor |
2 |
Semi-conductive conductor screen |
3 |
XLPE insulation |
4 |
Semi-conductive insulation screen |
5 |
Copper tape screen |
6 |
Non-woven cloth tape or glass fiber tape |
7 |
Non-flame retardant or flame retardant PVC sheath |
Technical Characteristics of 3.6/6kV for CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable, 1-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
1x25 |
2.5 |
1.5 |
19 |
0.727 |
1.20 |
576 |
421 |
1x35 |
2.5 |
1.5 |
20 |
0.524 |
0.868 |
695 |
479 |
1x50 |
2.5 |
2.0 |
21 |
0.387 |
0.641 |
860 |
550 |
1x70 |
2.5 |
2.0 |
23 |
0.268 |
0.443 |
1081 |
648 |
1x95 |
2.5 |
2.0 |
24 |
0.193 |
0.320 |
1350 |
762 |
1x 120 |
2.5 |
2.0 |
26 |
0.153 |
0.253 |
1640 |
897 |
1x 150 |
2.5 |
2.0 |
27 |
0.124 |
0.206 |
1947 |
1079 |
1x 185 |
2.5 |
2.0 |
29 |
0.0991 |
0.164 |
2302 |
1156 |
1x240 |
2.6 |
2.0 |
32 |
0.0754 |
0.125 |
2886 |
1400 |
1x300 |
2.8 |
2.0 |
34 |
0.0601 |
0.100 |
3483 |
1626 |
1x400 |
3.0 |
2.5 |
38 |
0.047 |
0.0778 |
4477 |
2001 |
1x500 |
3.2 |
2.5 |
41 |
0.0366 |
0.0605 |
5452 |
2357 |
Technical Characteristics of 6/6kV,6/10kV for CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable, 1-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Diamete (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
1x25 |
3.4 |
2.0 |
20 |
0.727 |
1.20 |
598 |
443 |
1x35 |
3.4 |
2.0 |
22 |
0.524 |
0.868 |
719 |
502 |
1x50 |
3.4 |
2.0 |
23 |
0.387 |
0.641 |
884 |
575 |
1x70 |
3.4 |
2.0 |
24 |
0.268 |
0.443 |
1097 |
664 |
1x95 |
3.4 |
2.0 |
26 |
0.193 |
0.320 |
1378 |
790 |
1x 120 |
3.4 |
2.0 |
28 |
0.153 |
0.253 |
1658 |
916 |
1x 150 |
3.4 |
2.0 |
30 |
0.124 |
0.206 |
1967 |
1038 |
1x 185 |
3.4 |
2.0 |
31 |
0.0991 |
0.164 |
2335 |
1190 |
1x240 |
3.4 |
2.0 |
34 |
0.0754 |
0.125 |
2908 |
1423 |
1x300 |
3.4 |
2.0 |
36 |
0.0601 |
0.100 |
3507 |
1650 |
1x400 |
3.4 |
2.5 |
39 |
0.0470 |
0.0778 |
4503 |
2027 |
1x500 |
3.4 |
2.5 |
42 |
0.0366 |
0.0605 |
5479 |
2384 |
Technical Characteristics of 8.7/10kV,8.7/15kV for CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable, 1-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
1x25 |
4.5 |
1.8 |
23 |
0.727 |
1.20 |
680 |
525 |
1x35 |
4.5 |
1.8 |
24 |
0.524 |
0.868 |
804 |
587 |
1x50 |
4.5 |
1.9 |
25 |
0.387 |
0.641 |
984 |
674 |
1x70 |
4.5 |
1.9 |
27 |
0.268 |
0.443 |
1201 |
768 |
1x95 |
4.5 |
2.0 |
29 |
0.193 |
0.320 |
1490 |
902 |
1x 120 |
4.5 |
2.0 |
30 |
0.153 |
0.253 |
1765 |
1022 |
1x 150 |
4.5 |
2.1 |
32 |
0.124 |
0.206 |
2091 |
1162 |
1x 185 |
4.5 |
2.1 |
34 |
0.0991 |
0.164 |
2452 |
1307 |
1x240 |
4.5 |
2.2 |
36 |
0.0754 |
0.125 |
3034 |
1548 |
1x300 |
4.5 |
2.4 |
39 |
0.0601 |
0.100 |
3672 |
1815 |
1x400 |
4.5 |
2.4 |
42 |
0.047 |
0.0778 |
4646 |
2170 |
1x500 |
4.5 |
2.5 |
45 |
0.0366 |
0.0605 |
5651 |
2556 |
Technical Characteristics of 12/20kVfor CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable, 1-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
1x35 |
5.5 |
2.0 |
27 |
0.524 |
0.868 |
979 |
762 |
1x50 |
5.5 |
2.0 |
29 |
0.387 |
0.641 |
1155 |
846 |
1x70 |
5.5 |
2.0 |
30 |
0.268 |
0.443 |
1393 |
959 |
1x95 |
5.5 |
2.0 |
32 |
0.193 |
0.320 |
1681 |
1093 |
1x 120 |
5.5 |
2.0 |
34 |
0.153 |
0.253 |
1979 |
1236 |
1x 150 |
5.5 |
2.0 |
35 |
0.124 |
0.206 |
2301 |
1373 |
1x 185 |
5.5 |
2.0 |
38 |
0.0991 |
0.164 |
2718 |
1573 |
1x240 |
5.5 |
2.5 |
40 |
0.0754 |
0.125 |
3302 |
1817 |
1x300 |
5.5 |
2.5 |
43 |
0.0601 |
0.100 |
3941 |
2084 |
1x400 |
5.5 |
2.5 |
45 |
0.0470 |
0.0778 |
4931 |
2455 |
1x500 |
5.5 |
2.5 |
48 |
0.0366 |
0.0605 |
5956 |
2861 |
Technical Characteristics of 21/35kVfor CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable, 1-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
1x50 |
9.3 |
2.0 |
37 |
0.387 |
0.641 |
1609 |
1360 |
1x70 |
9.3 |
2.5 |
38 |
0.268 |
0.443 |
1850 |
1417 |
1x95 |
9.3 |
2.5 |
40 |
0.193 |
0.320 |
2193 |
1605 |
1x 120 |
9.3 |
2.5 |
42 |
0.153 |
0.253 |
2498 |
1756 |
1x 150 |
9.3 |
2.5 |
44 |
0.124 |
0.206 |
2839 |
1910 |
1x 185 |
9.3 |
2.5 |
45 |
0.0991 |
0.164 |
3248 |
2102 |
1x240 |
9.3 |
2.5 |
48 |
0.0754 |
0.125 |
3881 |
2395 |
1x300 |
9.3 |
3.0 |
50 |
0.0601 |
0.100 |
4529 |
2672 |
1x400 |
9.3 |
3.0 |
53 |
0.0470 |
0.0778 |
5570 |
3094 |
1x500 |
9.3 |
3.0 |
55 |
0.0366 |
0.0605 |
6690 |
3595 |
Technical Characteristics of 26/35kV,26/35kV for CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable, 1-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
1x50 |
10.5 |
2.2 |
39 |
0.387 |
0.641 |
1758 |
1449 |
1x70 |
10.5 |
2.4 |
41 |
0.268 |
0.443 |
2035 |
1604 |
1x95 |
10.5 |
2.4 |
43 |
0.193 |
0.320 |
2355 |
1767 |
1x 120 |
10.5 |
2.4 |
44 |
0.153 |
0.253 |
2666 |
1923 |
1x 150 |
10.5 |
2.5 |
46 |
0.124 |
0.206 |
3031 |
2103 |
1x 185 |
10.5 |
2.5 |
48 |
0.0991 |
0.164 |
3427 |
2282 |
1x240 |
10.5 |
2.6 |
50 |
0.0754 |
0.125 |
4070 |
2584 |
1x300 |
10.5 |
2.7 |
53 |
0.0601 |
0.100 |
4748 |
2891 |
1x400 |
10.5 |
2.8 |
56 |
0.0470 |
0.0778 |
5801 |
3325 |
1x500 |
10.5 |
2.9 |
59 |
0.0366 |
0.0605 |
6623 |
4076 |
Construction of 0.6/1kV 3-core for CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable

No |
Construction and materials |
1 |
Copper or aluminum conductor |
2 |
XLPE insulation |
3 |
PP yarn or glass fiber rope filler |
4 |
Non-woven cloth tape or glass fiber tape |
5 |
Non-flame retardant or flame retardant PVC outer sheath |
Technical Characteristics of 0.6/1kV for CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable, 3-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x 1.5 |
0.7 |
1.5 |
10 |
12.1 |
--- |
145 |
--- |
3x2.5 |
0.7 |
1.5 |
11 |
7.41 |
12.1 |
185 |
140 |
3x4 |
0.7 |
1.5 |
12 |
4.61 |
7.41 |
250 |
175 |
3x6 |
0.7 |
1.5 |
13 |
3.08 |
4.61 |
320 |
210 |
3x10 |
0.7 |
1.5 |
15 |
1.83 |
3.08 |
450 |
260 |
3x16 |
0.7 |
1.5 |
17 |
1.15 |
1.91 |
640 |
340 |
3x25 |
0.9 |
2.0 |
21 |
0.727 |
1.20 |
940 |
470 |
3x35 |
0.9 |
2.0 |
23 |
0.524 |
0.868 |
1260 |
600 |
3x50 |
1.0 |
2.0 |
27 |
0.387 |
0.641 |
1670 |
730 |
3x70 |
1.1 |
2.0 |
30 |
0.268 |
0.443 |
2280 |
970 |
3x95 |
1.1 |
2.0 |
34 |
0.193 |
0.320 |
3020 |
1240 |
3x 120 |
1.2 |
2.5 |
38 |
0.153 |
0.253 |
3790 |
1540 |
3x 150 |
1.4 |
2.5 |
42 |
0.124 |
0.206 |
4750 |
1940 |
3x 185 |
1.6 |
2.5 |
45 |
0.0991 |
0.164 |
5654 |
2248 |
3x240 |
1.7 |
3.0 |
51 |
0.0754 |
0.125 |
7243 |
2723 |
Construction of 3.6/6kV to 26/35kV 3-core for CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable

No |
Construction and materials |
1 |
Copper or aluminum conductor |
2 |
Semi-conductive conductor screen |
3 |
XLPE insulation |
4 |
Semi-conductive insulation screen |
5 |
Copper tape screen |
6 |
PP yarn or glass fiber rope filler |
7 |
Non-woven cloth tape or glass fiber tape |
8 |
Non-flame retardant or flame retardant PVC outer sheath |
Technical Characteristics of 3.6/6kV for CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable, 3-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x25 |
2.5 |
2.5 |
40 |
0.727 |
1.20 |
576 |
421 |
3x35 |
2.5 |
2.5 |
43 |
0.524 |
0.868 |
695 |
479 |
3x50 |
2.5 |
2.5 |
46 |
0.387 |
0.641 |
850 |
550 |
3x70 |
2.5 |
2.5 |
49 |
0.268 |
0.443 |
1081 |
648 |
3x95 |
2.5 |
3.0 |
53 |
0.193 |
0.320 |
1350 |
762 |
3x 120 |
2.5 |
3.0 |
57 |
0.153 |
0.253 |
1640 |
897 |
3x 150 |
2.5 |
3.0 |
61 |
0.124 |
0.206 |
1947 |
1019 |
3x 185 |
2.5 |
3.0 |
63 |
0.0991 |
0.164 |
2302 |
1152 |
3x240 |
2 6 |
3 5 |
70 |
0 0754 |
0 125 |
2886 |
1400 |
3x300 |
2.8 |
3.5 |
75 |
0.0601 |
0.100 |
3351 |
1626 |
Technical Characteristics of 6/6kV,6/10kV for CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable, 3-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x25 |
3.4 |
2.5 |
42 |
0.727 |
1.20 |
1895 |
1430 |
3x35 |
3.4 |
2.5 |
44 |
0.524 |
0.868 |
2293 |
1640 |
3x50 |
3.4 |
2.5 |
46 |
0.387 |
0.641 |
2812 |
1881 |
3x70 |
3.4 |
3.0 |
50 |
0.268 |
0.443 |
3508 |
2205 |
3x95 |
3.4 |
3.0 |
54 |
0.193 |
0.320 |
4402 |
2635 |
3x 120 |
3.4 |
3.0 |
58 |
0.153 |
0.253 |
5319 |
3087 |
3x 150 |
3.4 |
3.0 |
62 |
0.124 |
0.206 |
6309 |
3518 |
3x 185 |
3.4 |
3.0 |
65 |
0.0991 |
0.164 |
7319 |
3877 |
3x240 |
3.4 |
3.5 |
71 |
0.0754 |
0.125 |
9218 |
4753 |
3x300 |
3.4 |
3.5 |
75 |
0.0601 |
0.100 |
11159 |
5577 |
Technical Characteristics of 8.7/10kV,8.7/15kV for CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable, 3-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x25 |
4.5 |
2.8 |
50 |
0.727 |
1.20 |
2537 |
2072 |
3x35 |
4.5 |
2.9 |
53 |
0.524 |
0.868 |
2985 |
2334 |
3x50 |
4.5 |
2.9 |
55 |
0.387 |
0.641 |
3529 |
2598 |
3x70 |
4.5 |
2.9 |
58 |
0.268 |
0.443 |
4197 |
2895 |
3x95 |
4.5 |
3.3 |
63 |
0.193 |
0.320 |
5230 |
3462 |
3x 120 |
4.5 |
3.6 |
66 |
0.153 |
0.253 |
6120 |
3888 |
3x 150 |
4.5 |
3.6 |
70 |
0.124 |
0.206 |
7207 |
4416 |
3x 185 |
4.5 |
3.6 |
74 |
0.0991 |
0.164 |
8378 |
4935 |
3x240 |
4.5 |
3.6 |
79 |
0.0754 |
0.125 |
10177 |
5712 |
3x300 |
4.5 |
3.8 |
84 |
0.0601 |
0.100 |
12159 |
6577 |
Technical Characteristics of 12/20kV for CU or AL conductor/XLPE Insulated /PVC Sheathed Power Cable, 3-core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x35 |
5.5 |
3.0 |
57 |
0.524 |
0.868 |
3348 |
2696 |
3x50 |
5.5 |
3.0 |
60 |
0.387 |
0.641 |
3904 |
2973 |
3x70 |
5.5 |
3.0 |
63 |
0.268 |
0.443 |
4623 |
3321 |
3x95 |
5.5 |
3.5 |
67 |
0.193 |
0.320 |
5593 |
3825 |
3x 120 |
5.5 |
3.5 |
71 |
0.153 |
0.253 |
6495 |
4262 |
3x 150 |
5.5 |
3.5 |
74 |
0.124 |
0.206 |
7637 |
4846 |
3x 185 |
5.5 |
3.5 |
78 |
0.0991 |
0.164 |
8803 |
5361 |
3x240 |
5.5 |
3.5 |
84 |
0.0754 |
0.125 |
10729 |
6263 |
3x300 |
5.5 |
4.0 |
89 |
0.0601 |
0.100 |
12723 |
7141 |
Construction of 0.6/1kV 3-core, CU or AL conductor/XLPE Insulated/Steel Tape Armored/PVC Sheathed Power Cable

No |
Construction and materials |
1 |
Copper or aluminum conductor |
2 |
XLPE insulation |
3 |
PP yarn or glass fiber rope filler |
4 |
Non-woven cloth tape or glass fiber tape |
5 |
Non-flame retardant or flame retardant PVC bedding |
6 |
Steel tape armor |
7 |
Non-flame retardant or flame retardant PVC outer sheath |
Technical Characteristics for 12/20kV, CU or AL conductor/XLPE Insulated/ Steel Tape Armored/ PVC Sheathed Power Cable, 3-Core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x 10 |
0.7 |
1.5 |
18 |
1.83 |
3.08 |
622 |
433 |
3x 16 |
0.7 |
2.0 |
22 |
1.15 |
1.91 |
1005 |
705 |
3x25 |
0.9 |
2.0 |
25 |
0.727 |
1.20 |
1371 |
898 |
3x35 |
0.9 |
2.0 |
27 |
0.524 |
0.868 |
1724 |
1061 |
3x50 |
1.0 |
2.0 |
30 |
0.387 |
0.641 |
2247 |
1300 |
3x70 |
1.1 |
2.5 |
35 |
0.268 |
0.443 |
3023 |
1697 |
3x95 |
1.1 |
2.5 |
39 |
0.193 |
0.320 |
3825 |
2026 |
3x 120 |
1.2 |
2.5 |
42 |
0.153 |
0.253 |
4642 |
2370 |
3x 150 |
1.4 |
3.0 |
48 |
0.124 |
0.206 |
5767 |
2926 |
3x 185 |
1.6 |
3.0 |
51 |
0.0991 |
0.164 |
6896 |
3391 |
3x240 |
1.7 |
3.0 |
56 |
0.0754 |
0.125 |
8617 |
4072 |
Construction of 3.6/6kV to 26/35kV 3-core, CU or AL conductor/XLPE Insulated /Steel Tape Armored/PVC Sheathed Power Cable

No |
Construction and materials |
|
1 |
Copper or aluminum conductor |
|
2 |
Semi-conductive conductor screen |
|
3 |
XLPE insulation |
|
4 |
Semi-conductive insulation screen |
|
5 |
Copper tape screen |
|
6 |
PP yarn or glass fiber rope filler |
|
7 |
Non-woven cloth tape or glass fiber tape |
|
8 |
Non-flame retardant or flame retardant PVC bedding |
|
9 |
Steel tape/wire armor |
|
10 |
- |
PVC |
Technical Characteristics for 3.6/6kV, CU or AL conductor/ XLPE Insulated/ Steel Tape Armored/ PVC Sheathed Power Cable, 3-Core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x25 |
2.5 |
2.6 |
46 |
0.727 |
1.20 |
2945 |
2480 |
3x35 |
2.5 |
2.6 |
49 |
0.524 |
0.868 |
3390 |
2739 |
3x50 |
2.5 |
2.8 |
52 |
0.387 |
0.641 |
4065 |
3135 |
3x70 |
2.5 |
2.8 |
55 |
0.268 |
0.443 |
4816 |
3513 |
3x95 |
2.5 |
3.1 |
60 |
0.193 |
0.320 |
5897 |
4129 |
3x 120 |
2.5 |
3.1 |
63 |
0.153 |
0.253 |
6844 |
4611 |
3x 150 |
2.5 |
3.3 |
67 |
0.124 |
0.206 |
7973 |
5182 |
3x 185 |
2.5 |
3.5 |
71 |
0.0991 |
0.164 |
9281 |
5838 |
3x240 |
2.6 |
3.6 |
77 |
0.0754 |
0.125 |
11229 |
6763 |
3x300 |
2.8 |
3.7 |
83 |
0.0601 |
0.100 |
14106 |
8524 |
Technical Characteristics for 6.6/6kV, 6/10kV, CU or AL conductor/XLPE Insulated/Steel Tape Armored/PVC Sheathed Power Cable, 3-Core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x25 |
3.4 |
2.6 |
47 |
0.727 |
1.20 |
3010 |
2544 |
3x35 |
3.4 |
2.8 |
50 |
0.524 |
0.868 |
3498 |
2847 |
3x50 |
3.4 |
2.8 |
53 |
0.387 |
0.641 |
4135 |
3205 |
3x70 |
3.4 |
3.1 |
56 |
0.268 |
0.443 |
4958 |
3655 |
3x95 |
3.4 |
3.1 |
61 |
0.193 |
0.320 |
5974 |
4206 |
3x 120 |
3.4 |
3.2 |
64 |
0.153 |
0.253 |
6969 |
4736 |
3x 150 |
3.4 |
3.6 |
69 |
0.124 |
0.206 |
8161 |
5370 |
3x 185 |
3.4 |
3.6 |
72 |
0.0991 |
0.164 |
9417 |
5975 |
3x240 |
3.4 |
3.6 |
78 |
0.0754 |
0.125 |
11340 |
6874 |
3x300 |
3.4 |
3.8 |
84 |
0.0601 |
0.100 |
14247 |
8665 |
Technical Characteristics for 8.7/10kV,8.7/15kV,CU or AL conductor/XLPE Insulated/ Steel Tape Armored/ PVC Sheathed Power Cable, 3-Core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x25 |
4.5 |
2.9 |
53 |
0.727 |
1.20 |
3500 |
3035 |
3x35 |
4.5 |
2.9 |
55 |
0.524 |
0.868 |
3329 |
3329 |
3x50 |
4.5 |
3.1 |
58 |
0.387 |
0.641 |
4679 |
3748 |
3x70 |
4.5 |
3.1 |
61 |
0.268 |
0.443 |
5410 |
4107 |
3x95 |
4.5 |
3.4 |
66 |
0.193 |
0.320 |
6567 |
4799 |
3x 120 |
4.5 |
3.4 |
70 |
0.153 |
0.253 |
7541 |
5308 |
3x 150 |
4.5 |
3.6 |
73 |
0.124 |
0.206 |
8674 |
5883 |
3x 185 |
4.5 |
3.6 |
77 |
0.0991 |
0.164 |
9991 |
6549 |
3x240 |
4 5 |
4 0 |
84 |
0 0754 |
0 125 |
12887 |
8421 |
3x300 |
4.5 |
4.0 |
89 |
0.0601 |
0.100 |
14974 |
9392 |
Technical Characteristics for 12/20kV, CU or AL conductor/XLPE Insulated/ Steel Tape Armored/PVC Sheathed Power Cable, 3-Core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x35 |
5.5 |
3.2 |
63 |
0.524 |
0.868 |
4840 |
4189 |
3x50 |
5.5 |
3.2 |
66 |
0.387 |
0.641 |
5463 |
4532 |
3x70 |
5.5 |
3.3 |
69 |
0.268 |
0.443 |
6346 |
5044 |
3x95 |
5.5 |
3.6 |
74 |
0.193 |
0.320 |
7457 |
5689 |
3x 120 |
5.5 |
3.6 |
77 |
0.153 |
0.253 |
8459 |
6227 |
3x 150 |
5.5 |
3.8 |
82 |
0.124 |
0.206 |
10555 |
7764 |
3x 185 |
5.5 |
4.0 |
86 |
0.0991 |
0.164 |
11925 |
8483 |
3x240 |
5.5 |
4.0 |
92 |
0.0754 |
0.125 |
13959 |
9494 |
3x300 |
5.5 |
4.2 |
97 |
0.0601 |
0.100 |
16314 |
10731 |
Construction of 0.6/1kV 3-core, CU or AL conductor/XLPE Insulated/Steel Wire Armored/PVC Sheathed Power Cable

No |
Construction and materials |
1 |
Copper or aluminum conductor |
2 |
XLPE insulation |
3 |
PP yarn or glass fiber rope filler |
4 |
Non-woven cloth tape or glass fiber tape |
5 |
Non-flame retardant or flame retardant PVC bedding |
6 |
Steel wire armor |
7 |
Non-flame retardant or flame retardant PVC sheath |
Technical Characteristics for 0.6/1kV, CU or AL conductor/ XLPE Insulated/ Steel Wire Armored/PVC Sheathed Power Cable, 3-Core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x 10 |
0.7 |
2.0 |
21 |
1.83 |
3.08 |
820 |
630 |
3x 16 |
0.7 |
2.0 |
25 |
1.15 |
1.91 |
1450 |
1150 |
3x25 |
0.9 |
2.0 |
28 |
0.727 |
1.20 |
1850 |
1400 |
3x35 |
0.9 |
2.0 |
31 |
0.524 |
0.868 |
2300 |
1650 |
3x50 |
1.0 |
2.0 |
32 |
0.387 |
0.641 |
2650 |
1750 |
3x70 |
1.1 |
2.5 |
38 |
0.268 |
0.443 |
3650 |
2350 |
3x95 |
1.1 |
2.5 |
41 |
0.193 |
0.320 |
4550 |
2800 |
3x 120 |
1.2 |
3.0 |
43 |
0.153 |
0.253 |
5450 |
3200 |
3x 150 |
1.4 |
3.0 |
48 |
0.124 |
0.206 |
7000 |
4200 |
3x 185 |
1.6 |
3.0 |
58 |
0.0991 |
0.164 |
9328 |
5849 |
3x240 |
1.7 |
3.5 |
65 |
0.0754 |
0.125 |
11236 |
6587 |
Construction of 3.6/6kV to 26/35kV 3-core, CU or AL conductor/XLPE Insulated/Steel Wire Armored/PVC Sheathed Power Cable

No |
Construction and materials |
|
1 |
Copper or aluminum conductor |
|
2 |
Semi-conductive conductor screen |
|
3 |
XLPE insulation |
|
4 |
Semi-conductive insulation screen |
|
5 |
Copper tape screen |
|
6 |
PP yarn or glass fiber rope filler |
|
7 |
Non-woven cloth tape or glass fiber tape |
|
8 |
Non-flame retardant or flame retardant PVC bedding |
|
9 |
Steel wire armor |
|
10 |
- |
PVC |
Technical Characteristics for 3.6/6kV,CU or AL conductor/XLPE Insulated/Steel Wire Armored/PVC Sheathed Power Cable, 3-Core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x25 |
2.5 |
2.5 |
49 |
0.727 |
1.20 |
4246 |
3781 |
3x35 |
2.5 |
3.0 |
52 |
0.524 |
0.868 |
4770 |
4119 |
3x50 |
2.5 |
3.0 |
57 |
0.387 |
0.641 |
6194 |
5263 |
3x70 |
2.5 |
3.0 |
60 |
0.268 |
0.443 |
7092 |
5790 |
3x95 |
2.5 |
3.0 |
64 |
0.193 |
0.320 |
8263 |
6495 |
3x 120 |
2.5 |
3.5 |
68 |
0.153 |
0.253 |
9422 |
7190 |
3x 150 |
2.5 |
3.5 |
71 |
0.124 |
0.206 |
10667 |
7876 |
3x 185 |
2.5 |
3.5 |
76 |
0.0991 |
0.164 |
12113 |
8671 |
3x240 |
2.6 |
3.5 |
81 |
0.0754 |
0.125 |
14361 |
9895 |
3x300 |
2.8 |
3.5 |
87 |
0.0601 |
0.100 |
16632 |
11050 |
Technical Characteristics for 6.6/6kV,6/10kV, CU or AL conductor/XLPE Insulated/ Steel Wire Armored/PVC Sheathed Power Cable, 3-Core
Jina conductor cross section area (mm) |
Nominal Insulation thickness
(mm) |
Jina sheath unene
(mm) |
Takriban Kwa ujumla Kipenyo
(mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x25 |
3.4 |
3.0 |
50 |
0.727 |
1.20 |
4337 |
3872 |
3x35 |
3.4 |
3.0 |
53 |
0.524 |
0.868 |
4863 |
4212 |
3x50 |
3.4 |
3.0 |
58 |
0.387 |
0.641 |
6302 |
5371 |
3x70 |
3.4 |
3.0 |
61 |
0.268 |
0.443 |
7177 |
5875 |
3x95 |
3.4 |
3.5 |
65 |
0.193 |
0.320 |
8431 |
6663 |
3x 120 |
3.4 |
3.5 |
69 |
0.153 |
0.253 |
9559 |
7326 |
3x 150 |
3.4 |
3.5 |
73 |
0.124 |
0.206 |
10873 |
8246 |
3x 185 |
3.4 |
3.5 |
76 |
0.0991 |
0.164 |
12256 |
8814 |
3x240 |
3 4 |
3 5 |
82 |
0 0754 |
0 125 |
14509 |
10044 |
3x300 |
3.4 |
4.0 |
88 |
0.0601 |
0.100 |
16821 |
11239 |
Technical Characteristics for 8.7/10kV,8.7/15kV,CU or AL conductor/XLPE Insulated/ Steel Wire Armored/ PVC Sheathed Power Cable, 3-Core
Jina conductor cross section area (mm) |
Nominal Insulation thickness
(mm) |
Jina sheath unene
(mm) |
Takriban Kwa ujumla Kipenyo
(mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x25 |
4.5 |
3.2 |
60 |
0.727 |
1.20 |
6058 |
5593 |
3x35 |
4.5 |
3.2 |
63 |
0.524 |
0.868 |
6661 |
6010 |
3x50 |
4.5 |
3.2 |
66 |
0.387 |
0.641 |
7456 |
6525 |
3x70 |
4.5 |
3.4 |
69 |
0.268 |
0.443 |
8376 |
7074 |
3x95 |
4.5 |
3.4 |
73 |
0.193 |
0.320 |
9657 |
7890 |
3x 120 |
4.5 |
3.5 |
76 |
0.153 |
0.253 |
10834 |
8602 |
3x 150 |
4.5 |
3.8 |
81 |
0.124 |
0.206 |
12160 |
9369 |
3x 185 |
4.5 |
3.8 |
85 |
0.0991 |
0.164 |
13661 |
10219 |
3x240 |
4.5 |
4.2 |
91 |
0.0754 |
0.125 |
15992 |
11527 |
3x300 |
4.5 |
4.2 |
96 |
0.0601 |
0.100 |
18262 |
12680 |
Technical Characteristics for 12/20kV, CU or AL conductor/XLPE Insulated/ Steel Wire Armored/ PVC Sheathed Power Cable, 3-Core
Jina conductor cross section area (mm) |
Nominal Insulation thickness (mm) |
Jina sheath unene (mm) |
Takriban Kwa ujumla Kipenyo (mm) |
Max DC Kondakta resistance at 20C (Ω/km) |
Approx weight of cable (kg/km) |
||
Cu |
Al |
Cu |
Al |
||||
3x35 |
5.5 |
3.5 |
68 |
0.524 |
0.868 |
7430 |
6752 |
3x50 |
5.5 |
3.5 |
70 |
0.387 |
0.641 |
8139 |
7208 |
3x70 |
5.5 |
3.5 |
74 |
0.268 |
0.443 |
9133 |
7831 |
3x95 |
5.5 |
3.5 |
78 |
0.193 |
0.320 |
10450 |
8682 |
3x 120 |
5.5 |
3.5 |
82 |
0.153 |
0.253 |
11612 |
9379 |
3x 150 |
5.5 |
4.0 |
86 |
0.124 |
0.206 |
12982 |
10191 |
3x 185 |
5.5 |
4.0 |
89 |
0.0991 |
0.164 |
14540 |
11098 |
3x240 |
5.5 |
4.0 |
95 |
0.0754 |
0.125 |
16751 |
12285 |
3x300 |
5.5 |
4.0 |
101 |
0.0601 |
0.100 |
19242 |
13660 |