- Laying Temperature: during laying environment temperature shall not be less than 0℃,the cable should be preheated.
- Operating Temperature: max permissible continuous operating temperature of conductor shall not exceed 70℃.
- Bending Radius: 16D for armored cable,8D for unarmored cable. D=actual outer diameter of cable ( mm )
- Standard: GB9330-88 or other standards required by customers.The requirement for flame retardant property is according to IEC 60332-3,category B and C.
- Packing: Steel/wooden reel, wooden reel, or steel reel.

Description |
Application Range |
Copper conductor/ PVC insulated/ PVC sheathed control cable |
For fixed laying indoors, in cable trench or conduit. |
Copper conductor/ PVC insulated/copper tape screened/ PVC sheathed control cable |
For fixed laying indoors,in cable trench or conduit when screen is required. |
Copper conductor/ PVC insulated/copper wire braiding screened/ PVC sheathed control cable |
|
Copper conductor/ PVC insulated/steel tape armored/ PVC sheathed control cable |
For fixed laying indoors,in cable trench, conduit or directly buried,the cable is able to bear larger mechanical force. |
Copper conductor/ PVC insulated/steel wire armored/ PVC sheathed control cable |
For fixed laying indoors,in cable trench, conduit or well.The cable is able to bear larger pulling force. |
Copper conductor/ PVC insulated/ PVC sheathed flexible control cable |
For fixed laying indoors when flexibility is required in moving. |
Copper conductor/ PVC insulated/copper wire braiding screened/ PVC sheathed control cable |
For fixed laying indoors when flexibility and screen are required in moving |

|
Nominal Cross Section Area of Conductor mm² |
|||||||
0.5 |
0.75 |
1 |
1.5 |
2.5 |
4 |
6 |
10 |
|
No of Cores |
||||||||
Cu/PVC/or S/PVC |
--- |
2 to 61 |
2 to 61 |
2 to 61 |
2 to 61 |
2 to 14 |
2 to 14 |
2 to 14 |
Cu/PVC/CWS/SWA/PVC |
--- |
4 to 61 |
4 to 61 |
4 to 61 |
4 to 61 |
4 to 14 |
4 to 14 |
4 to 14 |
Cu/PVC/STA/PVC |
--- |
7 to 61 |
7 to 61 |
7 to 61 |
4 to 61 |
4 to 14 |
4 to 14 |
4 to 14 |
Cu/PVC/SWA/PVC flexible |
--- |
19 to 61 |
19 to 61 |
7 to 61 |
7 to 61 |
4 to 14 |
4 to 14 |
4 to 14 |
Cu/PVC/CWS/PVC flexible |
4 to 44 |
4 to 44 |
4 to 44 |
4 to 44 |
4 to 37 |
--- |
--- |
--- |

PVC Insulted Control Cable, 450/750V Cu/PVC/PVC
1. Copper conductor
2. PVC insulation
3. PP yarn filler
4. Non-woven cloth tape
5. PVC overall sheath


PVC Insulated and Sheathed Control Cable, Cu/PVC/PVC
No of Cores x Nominal Cross Section Area of Conductor |
Class of Conductor |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Average Overall Diameter mm |
Max DC Conductor Resistance at 20℃ |
|
No x mm2 |
|
mm |
mm |
Max |
Min |
Ω/km |
2x0.75 |
1 |
0.6 |
1.2 |
6.4 |
8.0 |
24.5 |
2x0.75 |
2 |
0.6 |
1.2 |
6.6 |
8.4 |
24.5 |
2x1.0 |
1 |
0.6 |
1.2 |
6.8 |
8.4 |
18.1 |
2x1.0 |
2 |
0.6 |
1.2 |
6.8 |
8.8 |
18.1 |
2x1.5 |
1 |
0.7 |
1.2 |
7.6 |
9.4 |
12.1 |
2x1.5 |
2 |
0.7 |
1.2 |
7.8 |
10.0 |
12.1 |
2x2.5 |
1 |
0.8 |
1.2 |
8.6 |
10.5 |
7.41 |
2x2.5 |
2 |
0.8 |
1.2 |
9.0 |
11.5 |
7.41 |
2x4 |
1 |
0.8 |
1.2 |
9.6 |
11.5 |
4.61 |
2x4 |
2 |
0.8 |
1.2 |
10.0 |
12.5 |
4.61 |
2x6 |
1 |
0.8 |
1.2 |
10.5 |
12.5 |
3.08 |
2x6 |
2 |
0.8 |
1.2 |
11.0 |
14.0 |
3.08 |
2x10 |
2 |
1.0 |
1.2 |
14.0 |
17.5 |
1.83 |
3x0.75 |
1 |
0.6 |
1.2 |
6.8 |
8.4 |
24.5 |
3x0.75 |
2 |
0.6 |
1.2 |
7.0 |
8.8 |
24.5 |
3x1.0 |
1 |
0.6 |
1.2 |
7.0 |
8.8 |
18.1 |
3x1.0 |
2 |
0.6 |
1.2 |
7.2 |
9.2 |
18.1 |
3x1.5 |
1 |
0.7 |
1.2 |
8.0 |
9.8 |
12.1 |
3x1.5 |
2 |
0.7 |
1.2 |
8.2 |
10.5 |
12.1 |
3x2.5 |
1 |
0.8 |
1.2 |
9.2 |
11.0 |
7.41 |
3x2.5 |
2 |
0.8 |
1.2 |
9.4 |
12.0 |
7.41 |
3x4 |
1 |
0.8 |
1.2 |
10.0 |
12.5 |
4.61 |
3x4 |
2 |
0.8 |
1.2 |
10.5 |
13.5 |
4.61 |
3x6 |
1 |
0.8 |
1.5 |
11.5 |
14.0 |
3.08 |
3x6 |
2 |
0.8 |
1.5 |
12.0 |
15.0 |
3.08 |
3x10 |
2 |
1.0 |
1.5 |
14.5 |
18.5 |
1.83 |
4x0.75 |
1 |
0.6 |
1.2 |
7.2 |
9.0 |
24.5 |
4x0.75 |
2 |
0.6 |
1.2 |
7.4 |
9.6 |
24.5 |
4x1.0 |
1 |
0.6 |
1.2 |
7.6 |
9.4 |
18.1 |
4x1.0 |
2 |
0.6 |
1.2 |
7.8 |
10.0 |
18.1 |
4x1.5 |
1 |
0.7 |
1.2 |
8.6 |
10.5 |
12.1 |
4x1.5 |
2 |
0.7 |
1.2 |
9.0 |
11.5 |
12.1 |
4x2.5 |
1 |
0.8 |
1.2 |
10.0 |
12.0 |
7.41 |
4x2.5 |
2 |
0.8 |
1.2 |
10.0 |
13.0 |
7.41 |
4x4 |
1 |
0.8 |
1.5 |
11.5 |
14.0 |
4.61 |
4x4 |
2 |
0.8 |
1.5 |
12.0 |
15.0 |
4.61 |
4x6 |
1 |
0.8 |
1.5 |
12.5 |
15.0 |
3.08 |
4x6 |
2 |
0.8 |
1.5 |
13.0 |
16.5 |
3.08 |
4x10 |
2 |
1.0 |
1.5 |
16.0 |
20.0 |
1.83 |
5x0.75 |
1 |
0.6 |
1.2 |
7.8 |
9.6 |
24.5 |
5x0.75 |
2 |
0.6 |
1.2 |
8.0 |
10.5 |
24.5 |
5x1.0 |
1 |
0.6 |
1.2 |
8.2 |
10.0 |
18.1 |
5x1.0 |
2 |
0.6 |
1.2 |
8.4 |
11.0 |
18.1 |
5x1.5 |
1 |
0.7 |
1.2 |
9.4 |
11.5 |
12.1 |
5x1.5 |
2 |
0.7 |
1.2 |
9.8 |
12.5 |
12.1 |
5x2.5 |
1 |
0.8 |
1.5 |
11.5 |
14.0 |
7.41 |
5x2.5 |
2 |
0.8 |
1.5 |
11.5 |
14.5 |
7.41 |
5x4.0 |
1 |
0.8 |
1.5 |
12.5 |
16.0 |
4.61 |
5x4.0 |
2 |
0.8 |
1.5 |
13.0 |
16.5 |
4.61 |
5x6.0 |
1 |
0.8 |
1.5 |
14.0 |
17.5 |
3.08 |
5x6.0 |
2 |
0.8 |
1.5 |
14.5 |
18.0 |
3.08 |
5x10 |
2 |
1.0 |
1.7 |
18.0 |
22.5 |
1.83 |
7x0.75 |
1 |
0.6 |
1.2 |
8.4 |
10.5 |
24.5 |
7x0.75 |
2 |
0.6 |
1.2 |
8.8 |
11.0 |
24.5 |
7x1.0 |
1 |
0.6 |
1.2 |
9.0 |
11.0 |
18.1 |
7x1.0 |
2 |
0.6 |
1.2 |
9.2 |
11.5 |
18.1 |
7x1.5 |
1 |
0.7 |
1.2 |
10.0 |
12.5 |
12.1 |
7x1.5 |
2 |
0.7 |
1.2 |
10.5 |
13.5 |
12.1 |
7x2.5 |
1 |
0.8 |
1.5 |
12.5 |
15.0 |
7.41 |
7x2.5 |
2 |
0.8 |
1.5 |
12.5 |
16.0 |
7.41 |
7x4.0 |
1 |
0.8 |
1.5 |
13.5 |
16.5 |
4.61 |
7x4.0 |
2 |
0.8 |
1.5 |
14.0 |
17.5 |
4.61 |
7x6.0 |
1 |
0.8 |
1.5 |
15.0 |
18.0 |
3.08 |
7x6.0 |
2 |
0.8 |
1.5 |
15.5 |
19.5 |
3.08 |
7x10 |
2 |
1.0 |
1.7 |
20.0 |
24.0 |
1.83 |