Rubber Sheathed Flexible Mining Cable

 This product is suitable for movable electric appliances and excavators used in mines.





Upakuaji wa PDF

Maelezo

Lebo

 

Maelezo ya bidhaa

 

Joto la Uendeshaji: Max permissible continuous operating temperature of the conductor shall not exceed 65oC.

Kipenyo cha Kukunja: 6D,D = Actual outer diameter of cable (mm)

Kawaida: MT818- 19991 or other standards required by customers.

Ufungashaji: Steel/wooden reel, wooden reel or steel reel.

 

TYPE MY

 

1. Power conductor

2. Rubber insulation

3. Rubber filler

4. Ground conductor

5. Rubber sheath

 
Type, Description and Rated Voltage

 

Type

Maelezo

Rated Voltage

MY

Movable rubber sheathed flexible cable for mining purposes

0.38/0.66kV

MYQ

Light type movable rubber sheathed flexible cable for mining

purposes

0.3/0.5kV

MYP

Movable screened rubber sheathed flexible cable for mining

purposes

0.38/0.66kV

MC

Flexible rubber sheathed excavator cable

0.38/0.66kV

MCP

Flexible screened rubber sheathed excavator cable

0.38/0.66kV

MZ

Rubber sheathed drill cable for mining purpose

0.3/0.5kV

 

Safu ya Ugavi

 

Type

Rated Voltage

Idadi ya Cores

Nominal Area of Conductor sq.mm

KV

Power Core

Ground Core

Control Core

MY

0.38/0.66

1

3+1

50 to 400

4 to 70

4 to 25

 

-

MYP

0.38/0.66

3+1

4 to 70

4 to 25

-

MYQ

0.3/0.5

2,3,4,7, 12

1.0 to 2.5

-

-

MC

0.38/0.66

3+1+3

4 to 50

4 to 10

2.5 to 4

MCP

0.38/0.66

3+1+3

4 to 50

4 to 10

2.5 to 4

MZ

0.3/0.5

2.5~4

2.5 to 4

2.5 to 4

2.5 to 4

 

Rubber-sheathed flexible excavator cable

 

 

TYPE MC

 

1. Flexible copper conductor

2. Natural rubber insulation

3. Bare copper ground conductor

4. Control conductor

5. Natural rubber sheath

1. copper conductor

2. Natural rubber insulation

3. Bare copper ground conductor

4. Control conductor

5. Natural rubber sheath

 

Vipimo

 

Conductor DC Resistance of Mining Cable

Type

Nominal Area of Conductor

Max DC Conductor

resistance at 20C

(Ω/km)

Type

Jina

Area of

Kondakta

Max DC Conductor

resistance at 20C

(Ω/km)

Sq.mm

No tinned

Tinned

sq.mm

No tinned

Tinned

 

MYQ

1.0

19.5

20.2

 

 

 

 

 

 

 

 

MY

MYP

10

1.91

1.95

1.5

13.3

13.7

16

1.21

1.24

2.5

7.98

8.21

25

0.780

0.795

MZ

2.5

-

8.82

35

0.554

0.565

4

-

5.39

50

0.386

0.393

 

 

 

MC

MCP

4

-

5.09

70

0.272

0.277

6

-

3.39

95

0.206

0.210

10

-

1.95

120

0.161

0.164

16

-

1.24

150

0.129

0.132

25

-

0.795

185

0.106

0.108

35

-

0.565

240

0.0801

0.0187

50

-

0.393

300

0.0641

0.0654

MY

MYP

4

4.95

5.09

400

0.0486

0.0495

6

3.30

3.39

-

-

-

 