Andika W Umuyoboro umwe Umuyoboro ushobora gutwara 2kV

These cables are designed for use on electric mining locomotives and other mobile equipment of the gathering-reel type, where the cable must withstand constant lexing and reeling.





Gukuramo PDF

Ibisobanuro

Etiquetas

Ibipimocable brochure

 

  • ICEA S-75-381/NEMA WC 58
  • ASTM B 172
  • ASTM B 33
  • CAN/CSA C22.2 No.96

 

Ubwubatsirope wire manufacturers

 

silicone wire manufacturers
silver plated copper wire manufacturers

1. Stranded Tinned Copper Conductor

2. EPR Insulation

3. Reinforcement

4. CPE Jacket

 

  • Conductors: Stranded annealed tinned copper conductor.
  •  Insulation: EPR.
  • Reinforcement: A layer of polyester braid, applied between the insulation and sheath for mechanical strength.
  • Sheath: Chlorinated Polyethylene(CPE), black. Other sheath materials/color can be offered as an option.

 

Options
stainless steel cable tie manufacturers

 

Other jacket materials/color such as CSP/PCP/NBR/PVC are available upon request.

Two-layer jacket with reinforcing fiber between the two layers can be offered as an option.

 

Mechanical and Thermal Properties
cable brochure
  • Minimum Bending Radius: 6×OD
  • Maximum Operating Temperature: +90℃

 

Ibipimo n'uburemere
rope wire manufacturers

 

Ubwubatsi

No. of

Strands

Ubunini bw'izina

Nominal Overall Diameter

Nominal Weight

Ubushobozi

No. of

cores×AWG/kcmil

 

santimetero

mm

santimetero

mm

lbs/kft

kg / km

A

1×8

133

0.060

1.5

0.44

11.2

150

223

83

1×6

168

0.060

1.5

0.51

13.0

205

305

109

1×4

259

0.060

1.5

0.57

14.5

280

417

145

1×3

329

0.060

1.5

0.63

16.0

350

521

167

1×2

259

0.060

1.5

0.66

16.8

370

550

192

1×1

329

0.080

2.0

0.74

18.8

500

744

223

1×1/0

259

0.080

2.0

0.77

19.6

550

818

258

1×2/0

329

0.080

2.0

0.82

20.1

660

982

298

1×3/0

427

0.080

2.0

0.87

22.1

830

1235

345

1×4/0

532

0.080

2.0

0.93

23.6

950

1413

400

1×250

608

0.095

2.4

1.03

26.2

1240

1845

445

1×300

741

0.095

2.4

1.09

27.7

1400

2083

500

1×350

855

0.095

2.4

1.15

29.2

1480

2202

552

1×500

1221

0.095

2.4

1.31

33.3

2140

3184

695

Ampacity-Based on a conductor temperature of 90C and an ambient air temperature of 40C, per ICEA S-75-381

 