Typ W Single Dirigent Portable Power Kabel 2kV

These cables are designed for use on electric mining locomotives and other mobile equipment of the gathering-reel type, where the cable must withstand constant lexing and reeling.





PDF Download

Detailer

Tags

Standardencable brochure

 

  • ICEA S-75-381/NEMA WC 58
  • ASTM B 172
  • ASTM B 33
  • CAN/CSA C22.2 No.96

 

Baurope wire manufacturers

 

silicone wire manufacturers
silver plated copper wire manufacturers

1. Stranded Tinned Copper Conductor

2. EPR Insulation

3. Reinforcement

4. CPE Jacket

 

  • Conductors: Stranded annealed tinned copper conductor.
  •  Insulation: EPR.
  • Reinforcement: A layer of polyester braid, applied between the insulation and sheath for mechanical strength.
  • Sheath: Chlorinated Polyethylene(CPE), black. Other sheath materials/color can be offered as an option.

 

Options
stainless steel cable tie manufacturers

 

Other jacket materials/color such as CSP/PCP/NBR/PVC are available upon request.

Two-layer jacket with reinforcing fiber between the two layers can be offered as an option.

 

Mechanical and Thermal Properties
cable brochure
  • Minimum Bending Radius: 6×OD
  • Maximum Operating Temperature: +90℃

 

Dimensiounen a Gewiicht
rope wire manufacturers

 

Bau

No. of

Strands

Nominell Isolatioun Dicke

Nominal Overall Diameter

Nominal Weight

Ampasitéit

No. of

cores×AWG/kcmil

 

Zoll

mm

Zoll

mm

lbs/kft

kg/km

A

1×8

133

0.060

1.5

0.44

11.2

150

223

83

1×6

168

0.060

1.5

0.51

13.0

205

305

109

1×4

259

0.060

1.5

0.57

14.5

280

417

145

1×3

329

0.060

1.5

0.63

16.0

350

521

167

1×2

259

0.060

1.5

0.66

16.8

370

550

192

1×1

329

0.080

2.0

0.74

18.8

500

744

223

1×1/0

259

0.080

2.0

0.77

19.6

550

818

258

1×2/0

329

0.080

2.0

0.82

20.1

660

982

298

1×3/0

427

0.080

2.0

0.87

22.1

830

1235

345

1×4/0

532

0.080

2.0

0.93

23.6

950

1413

400

1×250

608

0.095

2.4

1.03

26.2

1240

1845

445

1×300

741

0.095

2.4

1.09

27.7

1400

2083

500

1×350

855

0.095

2.4

1.15

29.2

1480

2202

552

1×500

1221

0.095

2.4

1.31

33.3

2140

3184

695

Ampacity-Based on a conductor temperature of 90C and an ambient air temperature of 40C, per ICEA S-75-381

 

silicone wire manufacturers

cable brochure

rope wire manufacturers

silicone wire manufacturers

silver plated copper wire manufacturers

stainless steel cable tie manufacturers

Wann Dir un eise Produkter interesséiert sidd, kënnt Dir wielen Är Informatioun hei ze verloossen, a mir wäerte kuerz mat Iech a Kontakt sinn.


Schreift Äre Message hei a schéckt en un eis

Wann Dir un eise Produkter interesséiert sidd, kënnt Dir wielen Är Informatioun hei ze verloossen, a mir wäerte kuerz mat Iech a Kontakt sinn.


lbLuxembourgish